lNode Groups Type Names
|
lNode
|
lNode Type Names
|
A
|
Automatic control
|
ANCR
|
Neutral current regulator
|
ARCO
|
Reactive power control
|
ATCC
|
Automatic tap changer controller
|
AVCO
|
Voltage control
|
C
|
Supervisory control
|
CALH
|
Alarm handling
|
CCGR
|
Cooling group control
|
CILO
|
Interlocking
|
CPOW
|
Point-on-wave switching
|
CSWI
|
Switch controller
|
CSYN
|
Synchronizer controller
|
F
|
Functional blocks
|
FCNT
|
Counter
|
FCSD
|
Curve shape description
|
FFIL
|
Filter
|
FLIM
|
Control function output limitation
|
FPID
|
PID regulator
|
FRMP
|
Ramp function
|
FSPT
|
Set-point control function
|
FXOT
|
Action at over threshold
|
FXUT
|
Action at under threshold
|
G
|
Generic Function References
|
GAPC
|
Generic automatic process control
|
GGIO
|
Generic process I/O
|
GLOG
|
Generic log
|
GSAL
|
Generic security application
|
I
|
Interfacing and archiving
|
IARC
|
Archiving
|
IHMI
|
Human machine interface
|
ISAF
|
Safety alarm function
|
ITCI
|
Telecontrol interface
|
ITMI
|
Telemonitoring interface
|
K
|
Mechanical and non-electrical primary
equipment
|
KFAN
|
Fan
|
KFIL
|
Filter
|
KPMP
|
Pump
|
KTNK
|
Tank
|
KVLV
|
Valve control
|
S
|
System Logical Nodes
|
LLN0
|
-
|
M
|
Metering and measurement
|
MADV
|
Advanced Measurement unit
|
MDIF
|
Differential measurements
|
MENV
|
Environmental information
|
MFLK
|
Flicker Measurement unit
|
MHAI
|
Harmonics or interharmonics
|
MHAN
|
Non phase related harmonics or
interharmonics
|
MHYD
|
Hydrological information
|
MMDC
|
DC measurement
|
MMET
|
Meteorological information
|
MMTN
|
Metering
|
MMTR
|
Metering
|
MMXN
|
Non phase related Measurement
|
MMXU
|
Measurement
|
MSQI
|
Sequence and imbalance
|
MSTA
|
Metering Statistics
|
P
|
Protection Functions
|
PDIF
|
Differential
|
PDIR
|
Direction comparison
|
PDIS
|
Distance
|
PDOP
|
Directional overpower
|
PDUP
|
Directional underpower
|
PFRC
|
Rate of change of frequency
|
PHAR
|
Harmonic restraint
|
PHIZ
|
Ground detector
|
PIOC
|
Instantaneous overcurrent
|
PMRI
|
Motor restart inhibition
|
PMSS
|
Motor starting time supervision
|
POPF
|
Over power factor
|
PPAM
|
Phase angle measuring
|
PRTR
|
Rotor protection
|
PSCH
|
Protection scheme
|
PSDE
|
Sensitive directional earthfault
|
PTEF
|
Transient earth fault
|
PTHF
|
Tyristor protection
|
PTOC
|
Time overcurrent
|
PTOF
|
Overfrequency
|
PTOV
|
Overvoltage
|
PTRC
|
Protection trip conditioning
|
PTTR
|
Thermal overload
|
PTUC
|
Undercurrent
|
PTUF
|
Underfrequency
|
PTUV
|
Undervoltage
|
PUPF
|
Underpower factor
|
PVOC
|
Voltage controlled time overcurrent
|
PVPH
|
Volts per Hz
|
PZSU
|
ero speed or underspeed
|
Q
|
Power Quality Events Detection Related
|
QFVR
|
Frequency Variation
|
QITR
|
Current Transient
|
QIUB
|
Current Unbalance Variation
|
QVTR
|
Voltage Transient
|
QVUB
|
Voltage Unbalance Variation
|
QVVR
|
Voltage Variation
|
R
|
Protection Related Functions
|
RADR
|
Disturbance recorder channel analogue
|
RBDR
|
Disturbance recorder channel binary
|
RBRF
|
Breaker failure
|
RDIR
|
Directional element
|
RDRE
|
Disturbance recorder function
|
RDRS
|
Disturbance record handling
|
RFLO
|
Fault locator
|
RPSB
|
Power swing detection/blocking
|
RREC
|
Autoreclosing
|
RSOF
|
Switch-on-to-fault function
|
RSYN
|
Synchronism-check
|
RTPC
|
Teleprotection communication interfaces
|
S
|
Sensors, Monitoring
|
SARC
|
Monitoring and diagnostics for arcs
|
SCBR
|
Circuit breaker wear supervision
|
SIMG
|
Insulation medium supervision (gas)
|
SIML
|
Insulation medium supervision (liquid)
|
SLTC
|
Tap changer Supervision
|
SOPM
|
Supervision of Operating Mechanism
|
SPDC
|
Monitoring and diagnostics for partial
discharges
|
SPTR
|
Power Transformer Supervision
|
SSWI
|
Circuit Switch Supervision
|
STMP
|
Temperature supervision
|
SVBR
|
Vibration supervision
|
T
|
Instrument Transformer
|
TANG
|
Angle
|
TAXD
|
Axial displacement
|
TCTR
|
Current transformer
|
TDST
|
Distance
|
TFLW
|
Liquid flow
|
TFRQ
|
Frequency
|
THUM
|
Humidity
|
TLVL
|
Media level
|
TMGF
|
Magnetic field
|
TMVM
|
Movement sensor
|
TPOS
|
Position indicator
|
TPRS
|
Pressure sensor
|
TRTN
|
Rotation transmitter
|
TSND
|
Sound pressure sensor
|
TTMP
|
Temperature sensor
|
TTNS
|
Mechanical tension / stress
|
TVBR
|
Vibration sensor
|
TVTR
|
Voltage transformer
|
TWPH
|
Water acidity
|
X
|
Switchgear
|
XCBR
|
Circuit breaker
|
XSWI
|
Circuit switch
|
Y
|
Power transformer and related functions
|
YEFN
|
Earth fault neutralizer (Petersen coil)
|
YLTC
|
Tap changer
|
YPSH
|
Power shunt
|
YPTR
|
Power transformer
|
Z
|
Further (power system) equipment
|
ZAXN
|
Auxiliary network
|
ZBAT
|
Battery
|
ZBSH
|
Bushing
|
ZCAB
|
Power cable
|
ZCAP
|
Capacitor bank
|
ZCON
|
Converter
|
ZGEN
|
Generator
|
ZGIL
|
Gas insulated line
|
ZLIN
|
Power overhead line
|
ZMOT
|
Motor
|
ZREA
|
Reactor
|
ZRES
|
Neutral resistor
|
ZRRC
|
Rotating reactive component
|
ZSAR
|
Surge arrestor
|
ZSCR
|
Semi-conductor controlled rectifier
|
ZSMC
|
Synchronous machine
|
ZTCF
|
Thyristor controlled frequency
converter
|
ZTCR
|
Thyristor controlled reactive component
|